Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 99.430
Filter
1.
Ultrason Sonochem ; 105: 106865, 2024 May.
Article in English | MEDLINE | ID: mdl-38564909

ABSTRACT

To further enhance the application of nobiletin (an important active ingredient in Citrus fruits), we used ultrasonic homogenization-assisted antisolvent precipitation to create ultrafine particles of nobiletin (UPN). DMSO was used as the solvent, and deionized water was used as the antisolvent. When ultrasonication (670 W) and homogenization (16000 r/min) were synergistic, the solution concentration was 57 mg/mL, and the minimum particle size of UPN was 521.02 nm. The UPN samples outperformed the RN samples in terms of the inhibition of porcine pancreatic lipase, which was inhibited (by 500 mg/mL) by 68.41 % in the raw sample, 90.34 % in the ultrafine sample, and 83.59 % in the positive control, according to the data. Fourier transform infrared spectroscopy analysis revealed no chemical changes in the samples before or after preparation. However, the crystallinity of the processed ultrafine nobiletin particles decreased. Thus, this work offers significant relevance for applications in the realm of food chemistry and indirectly illustrates the expanded application potential of nobiletin.


Subject(s)
Flavones , Lipase , Particle Size , Solvents , Lipase/metabolism , Lipase/antagonists & inhibitors , Animals , Flavones/chemistry , Flavones/pharmacology , Swine , Solvents/chemistry , Pancreas/enzymology , Glycoside Hydrolase Inhibitors/pharmacology , Glycoside Hydrolase Inhibitors/chemistry , Sonication , alpha-Glucosidases/metabolism , Chemical Precipitation , Enzyme Inhibitors/pharmacology , Enzyme Inhibitors/chemistry
2.
J Mater Chem B ; 12(16): 3908-3916, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38567452

ABSTRACT

The fabrication of shape-selective coinage metal nanoclusters (MNCs) has promising applications due to their exceptional physical and chemical molecule-like properties. However, the stability of the specific geometry of the nanoclusters, such as their cubic shapes, is unclear and has been unraveled by assessing the nanoclusters' interactions with different environments. In this work, we investigate the morphological stability of cubic structured, coinage metal nanoclusters of varying sizes ranging from 14 to 1099 atoms. The impact of solvent environments like water and the presence of ionic liquids (IL) on the stabilization of the MNCs were assessed using molecular dynamics (MD) simulations. In general, smaller MNCs composed of less than 256 atoms encountered structural distortion easily compared to the larger ones, which preserved their cubic morphology with minimal surface aberrations in water. However, in the presence of 4M 1-butyl-1,1,1-trimethyl ammonium methane sulfonate [N1114][C1SO3] IL solution, the overall cubic shape of the MNCs was successfully preserved. Strikingly, it is observed that in contrast to the noble MNCs like Au and Ag, the cubic morphology for Cu MNCs with sizes less than 256 atoms exhibited significant stability even in the absence of IL.


Subject(s)
Copper , Metal Nanoparticles , Molecular Dynamics Simulation , Copper/chemistry , Metal Nanoparticles/chemistry , Ionic Liquids/chemistry , Particle Size , Surface Properties , Water/chemistry
3.
Food Chem ; 448: 139084, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38569403

ABSTRACT

Almond protein isolate (API) obtained from almond meal was processed using dynamic high-pressure microfluidisation (0, 40, 80, 120, and 160 MPa pressure; single pass). Microfluidisation caused significant reductions in the particle size and increased absolute zeta potential. SDS-PAGE analysis indicated reduction in band intensity and the complete disappearance of bands beyond 80 MPa. Structural analysis (by circular dichroism, UV-Vis, and intrinsic-fluorescence spectra) of the API revealed disaggregation (up to 80 MPa) and then re-aggregation beyond 80 MPa. Significant increments in protein digestibility (1.16-fold) and the protein digestibility corrected amino acid score (PDCAAS; 1.15-fold) were observed for the API (80 MPa) than control. Furthermore, significant improvements (P < 0.05) in the functional properties were observed, viz., the antioxidant activity, protein solubility, and emulsifying properties. Overall, the results revealed that moderate microfluidisation treatment (80 MPa) is an effective and sustainable technique for enhancing physico-chemical and functional attributes of API, thus potentially enabling its functional food/nutraceuticals application.


Subject(s)
Food Handling , Particle Size , Plant Proteins , Pressure , Prunus dulcis , Solubility , Prunus dulcis/chemistry , Plant Proteins/chemistry , Antioxidants/chemistry
4.
Food Chem ; 448: 139135, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38569405

ABSTRACT

The impacts of enzymatically produced acylglycerol and glycerin monostearate on the characteristics of gelatin-stabilized omega-3 emulsions and microcapsules were investigated. Tuna oil was enzymatically produced and the resulting acylglycerol was mixed with tuna oil at 12.5% (w/w) to prepare a novel oil phase. This oil phase was stabilized by gelatin to prepare oil-in-water emulsions and subsequent microcapsules via complex coacervation. The tuna oil with glycerin monostearate (GMS) at 1 and 2% (w/w) were used as controls. Results showed that both acylglycerol and GMS significantly reduced the emulsion droplet size and zeta potential, while increasing the viscoelasticity and stability. The diacylglycerol/monoacylglycerol were involved in the oil/water interfacial layer formation by lowering interfacial tension and increasing droplet surface hydrophobicity. Overall, the changed emulsion properties promoted the complex coacervation and contributed to the formation of microcapsules with improved oxidative stability. Therefore, enzymatically produced acylglycerol can develop high-quality stable omega-3 microencapsulated novel food ingredients.


Subject(s)
Capsules , Emulsions , Fatty Acids, Omega-3 , Fish Oils , Gelatin , Emulsions/chemistry , Capsules/chemistry , Gelatin/chemistry , Fatty Acids, Omega-3/chemistry , Fish Oils/chemistry , Animals , Particle Size , Glycerol/chemistry , Tuna , Glycerides/chemistry , Hydrophobic and Hydrophilic Interactions , Biocatalysis
5.
Luminescence ; 39(4): e4746, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38644460

ABSTRACT

The use of photochromism to increase the credibility of consumer goods has shown great promise. To provide mechanically dependable anticounterfeiting nanofibres, it has also been critical to improve the engineering processes of authentication patterns. Mechanically robust and photoluminescent electrospun poly(ethylene oxide)/glass (PGLS) nanofibres (150-350 nm) immobilized with nanoparticles of lanthanide-doped aluminate (NLA; 8-15 nm) were developed using electrospinning technology for anticounterfeiting purposes. The provided nanofibrous membranes changed colour from transparent to green when irradiated with ultraviolet light. By delivering NLA with homogeneous distribution without aggregations, we were able to keep the nanofibrous membrane transparent. When excited at 365 nm, NLA@PGLS nanofibres showed an emission intensity at 517 nm. The hydrophobicity of NLA@PGLS nanofibres improved by raising the pigment concentration as the contact angle was increased from 146.4° to 160.3°. After being triggered by ultraviolet light, NLA@PGLS showed quick and reversible photochromism without fatigue. It was shown that the suggested method can be applied to reliably produce various anticounterfeiting materials.


Subject(s)
Glass , Nanofibers , Polyethylene Glycols , Ultraviolet Rays , Nanofibers/chemistry , Polyethylene Glycols/chemistry , Glass/chemistry , Particle Size , Surface Properties
6.
J Chromatogr A ; 1722: 464856, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38579610

ABSTRACT

Complex mixture analysis requires high-efficiency chromatography columns. Although reversed phase liquid chromatography (RPLC) is the dominant approach for such mixtures, hydrophilic interaction liquid chromatography (HILIC) is an important complement to RPLC by enabling the separation of polar compounds. Chromatography theory predicts that small particles and long columns will yield high efficiency; however, little work has been done to prepare HILIC columns longer than 25 cm packed with sub-2 µm particles. In this work, we tested the slurry packing of 75 cm long HILIC columns with 1.7 µm bridged-ethyl-hybrid amide HILIC particles at 2,100 bar (30,000 PSI). Acetonitrile, methanol, acetone, and water were tested as slurry solvents, with acetonitrile providing the best columns. Slurry concentrations of 50-200 mg/mL were assessed, and while 50-150 mg/mL provided comparable results, the 150 mg/mL columns provided the shortest packing times (9 min). Columns prepared using 150 mg/mL slurries in acetonitrile yielded a reduced minimum plate height (hmin) of 3.3 and an efficiency of 120,000 theoretical plates for acenaphthene, an unretained solute. Para-toluenesulfonic acid produced the lowest hmin of 1.9 and the highest efficiency of 210,000 theoretical plates. These results identify conditions for producing high-efficiency HILIC columns with potential applications to complex mixture analysis.


Subject(s)
Acetonitriles , Benzenesulfonates , Hydrophobic and Hydrophilic Interactions , Acetonitriles/chemistry , Chromatography, Liquid/methods , Chromatography, Reverse-Phase/methods , Chromatography, Reverse-Phase/instrumentation , Methanol/chemistry , Solvents/chemistry , Acetone/chemistry , Particle Size , Pressure , Water/chemistry
7.
J Chromatogr A ; 1722: 464853, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38579611

ABSTRACT

This study presents a methodology for designing effective insulator-based electrokinetic (iEK) systems for separating tertiary microparticle samples, which can be extended to more complex samples. First, 144 distinct iEK microchannel designs were built considering different shapes and arrangements of the insulating posts. Second, a mathematical model was developed with COMSOL software to predict the retention time of each particle type in the microchannel, this allowed identifying the best channel designs for two distinct types of separations: charge-based and sized-based. Third, the experimental charge-based and size-based separations of the tertiary microparticle mixtures were performed employing the improved designs identified with COMSOL modeling. The experimental results demonstrated successful separation in terms of separation resolution and good agreement with COMSOL predictions. The findings from this study show that the proposed method for device design, which combines mathematical modeling with varying post shape and post arrangement is an effective approach for identifying iEK systems capable of separating complex microparticle samples.


Subject(s)
Equipment Design , Microfluidic Analytical Techniques/instrumentation , Models, Theoretical , Particle Size
8.
Chem Commun (Camb) ; 60(35): 4715-4718, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38596907

ABSTRACT

Chemically conjugated branched DNA was successfully synthesized by a copper-free click reaction to construct sophisticated and higher-order polyhedral DNA nanostructures with pre-defined units in one pot, which can be used as an efficient nanoplatform to precisely organize multiple gold nanoparticles in predesigned patterns.


Subject(s)
DNA , Gold , Metal Nanoparticles , Nanostructures , DNA/chemistry , Gold/chemistry , Nanostructures/chemistry , Metal Nanoparticles/chemistry , Click Chemistry , Particle Size
9.
J Chromatogr A ; 1722: 464891, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38608368

ABSTRACT

Particle size is a critical parameter of chromatographic resins that significantly affects protein separation. In this study, effects of resin particle sizes (31.26 µm, 59.85 µm and 85.22 µm named Aga-31, Aga-60 and Aga-85, respectively) on antibody adsorption capacity and separation performance of a hybrid biomimetic ligand were evaluated. Their performance was investigated through static adsorption and breakthrough assays to quantify static and dynamic binding capacity (Qmax and DBC). The static adsorption results revealed that the Qmax for hIgG was 152 mg/g resin with Aga-31, 151 mg/g resin with Aga-60, and 125 mg/g resin with Aga-85. Moreover, the DBC at 10% breakthrough for hIgG with a residence time of 2 min was determined to be 49.4 mg/mL for Aga-31, 45.9 mg/mL for Aga-60, and 38.9 mg/mL for Aga-85. The resins with smaller particle sizes exhibited significantly higher capacity compared to typical commercial agarose resins and a Protein A resin (MabSelect SuRe). Furthermore, the Aga-31 resin with the hybrid biomimetic ligand demonstrated exceptional performance in terms of IgG purity (>98%) and recovery (>96%) after undergoing 20 separation cycles from CHO cell supernatant. These findings are helpful in further chromatographic resin design for the industrial application of antibody separation and purification.


Subject(s)
Immunoglobulin G , Particle Size , Adsorption , Ligands , Immunoglobulin G/chemistry , Immunoglobulin G/isolation & purification , Chromatography, Affinity/methods , Biomimetic Materials/chemistry , Animals , Biomimetics/methods , Cricetulus , CHO Cells
10.
ACS Sens ; 9(4): 2066-2074, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38627252

ABSTRACT

In microfluidics, water droplets are often used as independent biochemical microreactor units, enabling the implementation of massively parallel screening assays where only a few of the reacting water droplets yield a positive result. However, sampling the product of these few successful reactions is an unsolved challenge. One possible solution is to use acoustic tweezers, which are lab-free, easily miniaturized, and biocompatible manipulation tools, and existing acoustic tweezers manipulating particles or cells, and water droplet manipulation in oil with an acoustic tweezer is absent. The first challenge in attempting to recover a few water droplets from a large batch is the selective manipulation of water droplets in an oil system. In this paper, we trap and manipulate single water droplets in oil using integrated single-beam (focused beam/vortex beam) acoustic tweezers for the first time. We find that water droplets with a diameter smaller than half a wavelength are trapped by acoustic vortices, while larger ones are better captured by focused acoustic beams. It is the first step to extract the target water droplet microreactors (positive ones) in an oil system and analyze their content. Compared to previous techniques, such as fluorescence-activated cell sorting (FACS), our technique is sparse, meaning that the sampling time is proportional to the number of droplets required and very insensitive to the total number of microreactors, making it well suited for large-scale screening assays.


Subject(s)
Acoustics , Oils , Water , Water/chemistry , Oils/chemistry , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Particle Size
11.
BMC Pulm Med ; 24(1): 203, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658883

ABSTRACT

BACKGROUND: Bronchial arterial embolization (BAE) has been accepted as an effective treatment for bronchiectasis-related hemoptysis. However, rare clinical trials compare different sizes of specific embolic agents. This study aims to evaluate whether different Embosphere microsphere sizes change the outcome of BAE. METHODS: A retrospective review was conducted on consecutive patients with bronchiectatic hemoptysis who were scheduled to undergo BAE treatment during a period from January 2018 to December 2022. The patients received BAE using microspheres of different sizes: group A patients were treated with 500-750 µm microspheres, and group B patients were treated with 700-900 µm microspheres. The cost of embolic microspheres (Chinese Yuan, CNY), duration of hospitalization, complications, and hemoptysis-free survival were compared between patients in group A and those in group B. A Cox proportional hazards regression model was used to identify predictors of recurrent hemoptysis. RESULTS: Median follow-up was 30.2 months (range, 20.3-56.5 months). The final analysis included a total of 112 patients (49-77 years of age; 45 men). The patients were divided into two groups: group A (N = 68), which received 500-750 µm Embosphere microspheres, and group B (N = 44), which received 700-900 µm Embosphere microspheres. Except for the cost of embolic microspheres(group A,5314.8 + 1301.5 CNY; group B, 3644.5 + 1192.3 CNY; p = 0.042), there were no statistically significant differences in duration of hospitalization (group A,7.2 + 1.4 days; group B, 8 + 2.4days; p = 0.550), hemoptysis-free survival (group A, 1-year, 2-year, 3-year, 85.9%, 75.8%, 62.9%; group B, 1-year, 2-year, 3-year, 88.4%, 81.2%,59.4%;P = 0.060), and complications(group A,26.5%; group B, 38.6%; p = 0.175) between the two groups. No major complications were observed. The multivariate analysis results revealed that the presence of cystic bronchiectasis (OR 1.61, 95% CI 1.12-2.83; P = 0.001) and systemic arterial-pulmonary shunts (SPSs) (OR 1.52, 95% CI 1.10-2.72; P = 0.028) were independent risk factors for recurrent bleeding. CONCLUSIONS: For the treatment of BAE in patients with bronchiectasis-related hemoptysis, 500-750 µm diameter Embosphere microspheres have a similar efficacy and safety profile compared to 700-900 µm diameter Embosphere microspheres, especially for those without SPSs or cystic bronchiectasis. Furthermore, the utilization of large-sized (700-900 µm) Embosphere microspheres is associated with the reduced cost of an embolic agent.


Subject(s)
Acrylic Resins , Bronchial Arteries , Bronchiectasis , Embolization, Therapeutic , Hemoptysis , Microspheres , Humans , Hemoptysis/therapy , Hemoptysis/etiology , Retrospective Studies , Male , Female , Embolization, Therapeutic/methods , Middle Aged , Aged , Bronchiectasis/complications , Bronchiectasis/therapy , Gelatin/administration & dosage , Gelatin/therapeutic use , Treatment Outcome , Particle Size
12.
Int J Nanomedicine ; 19: 3611-3622, 2024.
Article in English | MEDLINE | ID: mdl-38660022

ABSTRACT

Background: Mangiferin (MA), a bioactive C-glucosyl xanthone with a wide range of interesting therapeutic properties, has recently attracted considerable attention. However, its application in biomedicine is limited by poor solubility and bioavailability. Carbon dots (CDs), novel nanomaterials, have immense promise as carriers for improving the biopharmaceutical properties of active components because of their outstanding characteristics. Methods: In this study, a novel water-soluble carbon dot (MC-CDs) was prepared for the first time from an aqueous extract of Moutan Cortex Carbonisata, and characterized by various spectroscopies, zeta potential and high-resolution transmission electron microscopy (HRTEM). The toxicity effect was investigated using the CCK-8 assay in vitro. In addition, the potential of MC-CDs as carriers for improving the pharmacokinetic parameters was evaluated in vivo. Results: The results indicated that MC-CDs with a uniform spherical particle size of 1-5 nm were successfully prepared, which significantly increased the solubility of MA in water. The MC-CDs exhibited low toxicity in HT-22 cells. Most importantly, the MC-CDs effectively affected the pharmacokinetic parameters of MA in normal rats. UPLC-MS analysis indicated that the area under the maximum blood concentration of MA from mangiferin-MC-CDs (MA-MC-CDs) was 1.6-fold higher than that from the MA suspension liquid (MA control) after oral administration at a dose of 20 mg/kg. Conclusion: Moutan Cortex-derived novel CDs exhibited superior performance in improving the solubility and bioavailability of MA. This study not only opens new possibilities for the future clinical application of MA but also provides evidence for the development of green biological carbon dots as a drug delivery system to improve the biopharmaceutical properties of insoluble drugs.


Subject(s)
Biological Availability , Carbon , Paeonia , Particle Size , Rats, Sprague-Dawley , Solubility , Xanthones , Xanthones/pharmacokinetics , Xanthones/chemistry , Xanthones/administration & dosage , Animals , Carbon/chemistry , Carbon/pharmacokinetics , Male , Rats , Paeonia/chemistry , Drugs, Chinese Herbal/pharmacokinetics , Drugs, Chinese Herbal/chemistry , Drugs, Chinese Herbal/administration & dosage , Quantum Dots/chemistry , Quantum Dots/toxicity , Cell Line , Drug Carriers/chemistry , Drug Carriers/pharmacokinetics , Cell Survival/drug effects
13.
Int J Nanomedicine ; 19: 3589-3605, 2024.
Article in English | MEDLINE | ID: mdl-38645464

ABSTRACT

Purpose: This study aimed to develop a novel and feasible modification strategy to improve the solubility and antitumor activity of resiquimod (R848) by utilizing the supramolecular effect of 2-hydroxypropyl-beta-cyclodextrin (2-HP-ß-CD). Methods: R848-loaded PLGA nanoparticles modified with 2-HP-ß-CD (CD@R848@NPs) were synthesized using an enhanced emulsification solvent-evaporation technique. The nanoparticles were then characterized in vitro by several methods, such as scanning electron microscopy (SEM), differential scanning calorimetry (DSC), Fourier transform infrared (FTIR) spectroscopy, particle size analysis, and zeta potential analysis. Then, the nanoparticles were loaded with IR-780 dye and imaged using an in vivo imaging device to evaluate their biodistribution. Additionally, the antitumor efficacy and underlying mechanism of CD@R848@NPs in combination with an anti-TNFR2 antibody were investigated using an MC-38 colon adenocarcinoma model in vivo. Results: The average size of the CD@R848@NPs was 376 ± 30 nm, and the surface charge was 21 ± 1 mV. Through this design, the targeting ability of 2-HP-ß-CD can be leveraged and R848 is delivered to tumor-supporting M2-like macrophages in an efficient and specific manner. Moreover, we used an anti-TNFR2 antibody to reduce the proportion of Tregs. Compared with plain PLGA nanoparticles or R848, CD@R848@NPs increased penetration in tumor tissues, dramatically reprogrammed M1-like macrophages, removed tumors and prolonged patient survival. Conclusion: The new nanocapsule system is a promising strategy for targeting tumor, reprogramming tumor -associated macrophages, and enhancement immunotherapy.


Subject(s)
2-Hydroxypropyl-beta-cyclodextrin , Colonic Neoplasms , Imidazoles , Nanoparticles , Polylactic Acid-Polyglycolic Acid Copolymer , Tumor-Associated Macrophages , Imidazoles/chemistry , Imidazoles/pharmacology , Imidazoles/pharmacokinetics , Colonic Neoplasms/drug therapy , Colonic Neoplasms/pathology , Animals , Nanoparticles/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer/chemistry , 2-Hydroxypropyl-beta-cyclodextrin/chemistry , Tumor-Associated Macrophages/drug effects , Cell Line, Tumor , Mice , Humans , Tissue Distribution , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Antineoplastic Agents/pharmacokinetics , Antineoplastic Agents/administration & dosage , Particle Size , Drug Carriers/chemistry , Drug Carriers/pharmacokinetics
14.
Sci Rep ; 14(1): 9182, 2024 04 22.
Article in English | MEDLINE | ID: mdl-38649422

ABSTRACT

In order to obtain high yield pomelo peel pectin with better physicochemical properties, four pectin extraction methods, including hot acid extraction (HAE), microwave-assisted extraction (MAE), ultrasound-assisted extraction, and enzymatic assisted extraction (EAE) were compared. MAE led to the highest pectin yield (20.43%), and the lowest pectin recovery was found for EAE (11.94%). The physicochemical properties of pomelo peel pectin obtained by different methods were also significantly different. Pectin samples obtained by MAE had the highest methoxyl content (8.35%), galacturonic acid content (71.36%), and showed a higher apparent viscosity, thermal and emulsion stability. The pectin extracted by EAE showed the highest total phenolic content (12.86%) and lowest particle size (843.69 nm), showing higher DPPH and ABTS scavenging activities than other extract methods. The pectin extracted by HAE had the highest particle size (966.12 nm) and degree of esterification (55.67%). However, Fourier-transform infrared spectroscopy showed that no significant difference occurred among the different methods in the chemical structure of the extracted pectin. This study provides a theoretical basis for the industrial production of pomelo peel pectin.


Subject(s)
Citrus , Hexuronic Acids , Pectins , Pectins/chemistry , Pectins/isolation & purification , Citrus/chemistry , Viscosity , Particle Size , Microwaves , Spectroscopy, Fourier Transform Infrared , Plant Extracts/chemistry , Plant Extracts/isolation & purification , Chemical Fractionation/methods , Chemical Phenomena , Fruit/chemistry , Antioxidants/chemistry , Antioxidants/isolation & purification , Antioxidants/pharmacology , Phenols/analysis , Phenols/chemistry , Phenols/isolation & purification , Esterification
15.
Environ Sci Technol ; 58(16): 6934-6944, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38651174

ABSTRACT

Stratospheric aerosol injection (SAI) is proposed as a means of reducing global warming and climate change impacts. Similar to aerosol enhancements produced by volcanic eruptions, introducing particles into the stratosphere would reflect sunlight and reduce the level of warming. However, uncertainties remain about the roles of nucleation mechanisms, ionized molecules, impurities (unevaporated residuals of injected precursors), and ambient conditions in the generation of SAI particles optimally sized to reflect sunlight. Here, we use a kinetic ion-mediated and homogeneous nucleation model to study the formation of H2SO4 particles in aircraft exhaust plumes with direct injection of H2SO4 vapor. We find that under the conditions that produce particles of desired sizes (diameter ∼200-300 nm), nucleation occurs in the nascent (t < 0.01 s), hot (T = 360-445 K), and dry (RH = 0.01-0.1%) plume and is predominantly unary. Nucleation on chemiions occurs first, followed by neutral new particle formation, which converts most of the injected H2SO4 vapor to particles. Coagulation in the aging and diluting plumes governs the subsequent evolution to a narrow (σg = 1.3) particle size distribution. Scavenging by exhaust soot is negligible, but scavenging by acid impurities or incomplete H2SO4 evaporation in the hot exhaust plume and enhanced background aerosols can matter. This research highlights the need to obtain laboratory and/or real-world experiment data to verify the model prediction.


Subject(s)
Aerosols , Aircraft , Particle Size , Vehicle Emissions , Atmosphere/chemistry , Air Pollutants/chemistry
16.
AAPS PharmSciTech ; 25(4): 73, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38575825

ABSTRACT

The focus of the research was to overcome the limitations of metoclopramide (MTC) when administered intranasally. The aim was to improve its bioavailability, increase patient compliance, and prolong its residence time in the nasal cavity. MTC-loaded liposomes were prepared by applying the film hydration method. A study was conducted to determine how formulation variables affected encapsulation efficiency (EE %), mean particle size (MPS), and zeta potential (ZP). The MTC-liposomes were further loaded into the in situ gel (gellan gum) for longer residence times following intranasal administration. pH, gelling time, and in vitro release tests were conducted on the formulations produced. In vivo performance of the MTC-loaded in situ gels was appraised based on disparate parameters such as plasma peak concentration, plasma peak time, and elimination coefficient compared to intravenous administration. When the optimal liposome formulation contained 1.98% of SPC, 0.081% of cholesterol, 97.84% of chloroform, and 0.1% of MTC, the EE of MTC was 83.21%, PS was 107.3 nm. After 5 h, more than 80% of the drug was released from MTC-loaded liposome incorporated into gellan gum in situ gel formulation (Lip-GG), which exhibited improved absorption and higher bioavailability compared to MTC loaded into gellan gum in situ gel (MTC-GG). Acceptable cell viability was also achieved. It was found out that MTC-loaded liposomal in situ gel formulations administered through the nasal route could be a better choice than other options due to its ease of administration, accurate dosing, and higher bioavailability in comparison with MTC-GG.


Subject(s)
Liposomes , Metoclopramide , Rabbits , Humans , Animals , Biological Availability , Administration, Intranasal , Nausea , Lipids , Gels , Particle Size , Drug Delivery Systems
17.
ACS Appl Mater Interfaces ; 16(15): 18627-18642, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38590224

ABSTRACT

We investigated the distribution of intratracheally administered thiol-organosilica (thiol-OS) particles in mouse lungs. Toward this end, single doses of thiol-OS particles containing fluorescein (140 nm in diameter) (F140) and rhodamine B (Rh) (Rh160, Rh280, Rh420, Rh640, and Rh1630 with diameters of 160, 280, 420, 640, and 1630 nm, respectively) were administered. After 24 h, fluorescence imaging revealed homogeneous fluorescence with a patchier pattern on the lung surface and no difference among the six particle sizes. Simultaneous dual administration of Rh and F140 particles did not reveal any size-dependent differences in the lung surface fluorescence. Fluorescence microscopy of the lung sections revealed a similar tissue distribution in the fluorescent areas of Rhs and F140. Some fluorescent areas showed one type of particle fluorescence or only one fluorescence. Cellular distribution of particles was observed in bronchoalveolar lavage cells and lung sections under a high magnification, and correlative light and electron microscopy revealed large cells with fluorescence corresponding to both particle types and small cells with fluorescence of individual particle types, indicating a cell-subset-dependent particle size effect. Rh280, Rh420, and Rh640 exhibited significant size effects and were taken up by alveolar macrophages. Extracellular particles were observed, indicating that saturation exceeded the particle dose threshold in the alveoli. F140 taken up by small and large macrophages colocalized with CD68, CD11c, and CD11b and correlated with CD11c. The size effect, intracellular localization, and extracellular distribution of particles provide insights into lung and systemic drug delivery.


Subject(s)
Lung , Sulfhydryl Compounds , Mice , Animals , Particle Size , Chemical Phenomena , Macrophages , Coloring Agents
18.
Anal Chim Acta ; 1304: 342534, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38637035

ABSTRACT

The traceability of in vitro diagnostics or drug products is based on the accurate quantification of proteins. In this study, we developed an absolute quantification approach for proteins. This method is based on calibrated particle counting using electrospray-differential mobility analysis (ES-DMA) coupled with a condensation particle counter (CPC). The absolute concentration of proteins was quantified with the observed protein particle number measured with ES-DMA-CPC, and the detection efficiency was determined by calibrators. The measurement performance and quantitative level were verified using two certificated reference materials, BSA and NIMCmAb. The linear regression fit for the detection efficiency values of three reference materials and one highly purified protein (myoglobin, BSA, NIMCmAb and fibrinogen) indicated that the detection efficiency and the particle size distribution of these proteins exhibited a linear relationship. Moreover, to explore the suitability of the detection efficiency-particle size curve for protein quantification, the concentrations of three typical proteinaceous particles, including two high molecular weight proteins (NIST reference material 8671 and D-dimer) and one protein complex (glutathione S-transferase dimer), were determined. This work suggests that this calibrated particle counting method is an efficient approach for nondestructive, rapid and accurate quantification of proteins, especially for measuring proteinaceous particles with tremendous size and without reference standards.


Subject(s)
Ion Mobility Spectrometry , Myoglobin , Particle Size , Glutathione Transferase , Gold
19.
Water Sci Technol ; 89(6): 1441-1453, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38557710

ABSTRACT

Despite facing many challenges, the exploration of using natural forces and mechanisms besides gravity to enhance particle settling has never ceased. A novel particle separator design, which utilizes multiple vortexes to enhance particle settling, was proposed in this study. The basic principle is using the fluid's energy to generate small swirling currents in a specially designed vortex claw generator. These currents bring suspended particles from the rapid and turbulent inflow to relatively quiet water regions, separating them from the main flows and reducing their travel distance to the wall. To verify the new separator design's performance, comparison studies were carried out in the laboratory using physical models. The results showed that the new design had much higher particle capture rates for the same inflow rates and tested particle sizes. Most importantly, it was able to effectively remove small particles, and particle capture rates were much less affected by fluctuations in inflow rates. Since most existing particle separators failed to perform well under large inflow rates, these characteristics make the new design stand out from other separators. Due to its special structure, its treatment capacity can also be easily increased without changing its horizontal separator size.


Subject(s)
Technology , Particle Size
20.
PLoS One ; 19(4): e0300050, 2024.
Article in English | MEDLINE | ID: mdl-38574045

ABSTRACT

The quantification of aerosol size distributions is crucial for understanding the climate and health impacts of aerosols, validating models, and identifying aerosol sources. This work provides one of the first continuous measurements of aerosol size distribution from 1.02 to 8671 nm near the shore of Lake Michigan. The data were collected during the Lake Michigan Ozone Study (LMOS 2017), a comprehensive air quality measurement campaign in May and June 2017. The time-resolved (2-min) size distribution are reported herein alongside meteorology, remotely sensed data, gravimetric filters, and gas-phase variables. Mean concentrations of key aerosol parameters include PM2.5 (6.4 µg m-3), number from 1 to 3 nm (1.80x104 cm-3) and number greater than 3 nm (8x103 cm-3). During the field campaign, approximately half of days showed daytime ultrafine burst events, characterized by particle growth from sub 10 nm to 25-100 nm. A specific investigation of ultrafine lake spray aerosol was conducted due to enhanced ultrafine particles in onshore flows coupled with sustained wave breaking conditions during the campaign. Upon closer examination, the relationships between the size distribution, wind direction, wind speed, and wave height did not qualitatively support ultrafine particle production from lake spray aerosol; statistical analysis of particle number and wind speed also failed to show a relationship. The alternative hypothesis of enhanced ultrafine particles in onshore flow originating mainly from new particle formation activity is supported by multiple lines of evidence.


Subject(s)
Air Pollutants , Lakes , Lakes/analysis , Particle Size , Aerosolized Particles and Droplets , Particulate Matter/analysis , Aerosols/analysis , Air Pollutants/analysis , Environmental Monitoring
SELECTION OF CITATIONS
SEARCH DETAIL
...